IFM PN2293 Pressure Sensor with Display PN-025-REN14-MFRKG/U
IFM PN2293 Pressure Sensor with Display PN-025-REN14-MFRKG/US/ /V Arrived
Feature:
Pressure sensor with display
PN2293
PN-025-REN14-MFRKG/US/ /V
Two switching outputs, one of them programmable as IO-Link and one as analog output
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Product characteristics:
Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Measuring range
-1...25 bar-14.5...362.5 psi-0.1...2.5 MPa
Process connectionthreaded connection 1/4" NPT Internal thread
Application
Systemgold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C]-25...80
Min. bursting pressure
350 bar5075 psi35 MPa
Pressure rating
150 bar2175 psi15 MPa
Vacuum resistance
-1000 mbar-0.1 MPa
Type of pressurerelative pressure; vacuum
MAWP (for applications according to CRN)
70 bar1015 psi7 MPa
Electrical data
Operating voltage[V]18...30 DC; (to SELV/PELV)
Current consumption[mA]< 35
Min. insulation resistance[MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s]0.3
Integrated watchdogyes
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Outputs
Total number of outputs2
Output signalswitching signal; analog signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Max. voltage drop switching output DC[V]2
Permanent current rating of switching output DC[mA]250
Switching frequency DC[Hz]< 500
Number of analog outputs1
Analog current output[mA]4...20; (scalable 1:5)
Max. load[Ω]500
Analog voltage output[V]0...10; (scalable 1:5)
Min. load resistance[Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Measuring/setting range
Measuring range
-1...25 bar-14.5...362.5 psi-0.1...2.5 MPa
Analog start point
-1...20 bar-14.5...290 psi-0.1...2 MPa
Analog end point
4...25 bar58...362.5 psi0.4...2.5 MPa
Factory setting / CMPT = 2
Set point SP
-0.85...25 bar-12...362.5 psi-0.085...2.5 MPa
Reset point rP
-0.95...24.9 bar-13.5...361 psi-0.095...2.49 MPa
Min. difference between SP and rP
0.15 bar1.5 psi0.015 MPa
In steps of
0.05 bar0.5 psi0.005 MPa
Status_B High Resolution / CMPT = 3
Set point SP
-0.84...25 bar-12.2...362.6 psi-0.084...2.5 MPa
Reset point rP
-0.95...24.9 bar-13.7...361.1 psi-0.095...2.49 MPa
Min. difference between SP and rP
0.11 bar1.5 psi0.011 MPa
In steps of
0.01 bar0.1 psi0.001 MPa
Accuracy / deviations
Switch point accuracy[% of the span]< ± 0,4; (Turn down 1:1)
Repeatability[% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability[% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point[% of the span / 10 K]< ± 0,2; (-0...80 °C)
Temperature coefficient span[% of the span / 10 K]< ± 0,2; (-0...80 °C)
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%
Reaction times
Response time[ms]< 1.5
Delay time programmable dS, dr[s]0...50
Damping process value dAP[s]0...4
Damping for the analog output dAA[s]0...4
Max. response time analog output[ms]3
Software / programming
Parameter setting optionshysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port classA; (when pin 2 not connected: B)
Supported DeviceIDs
Type of operationDeviceID
Factory setting / CMPT = 2472
Status_B High Resolution / CMPT = 3988
Note
For further information please see the IODD PDF file at "Downloads"
Factory setting / CMPT = 2
ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time[ms]2.3
IO-Link resolution pressure[bar]0.01
IO-Link process data (cyclical)
Functionbit length
pressure14
binary switching information2
IO-Link functions (acyclical)application specific tag
Status_B High Resolution / CMPT = 3
ProfilesSmart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time[ms]3
IO-Link resolution pressure[bar]0.01
IO-Link process data (cyclical)
Functionbit length
pressure16
device status4
binary switching information2
IO-Link functions (acyclical)application specific tag
Operating conditions
Ambient temperature[°C]-25...80
Storage temperature[°C]-40...100
ProtectionIP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years]138
UL approval
UL approval numberJ012
Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight[g]223.5
Housingtubular
Dimensions[mm]Ø 34 / L = 90.7
Materialstainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM
Min. pressure cycles100 million
Tightening torque[Nm]> 50; (Depends on lubrication, seal and pressure rating)
Process connectionthreaded connection 1/4" NPT Internal thread
Restrictor element integratedno (can be retrofitted)
Displays / operating elements
Display
Display unit3 x LED, green (bar, psi, MPa)
Switching status2 x LED, yellow
Measured valuesalphanumeric display, red/green 4-digit
Remarks
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated
More Models:
EVC810 IIR200 PK5524 EVC005 II0011 EVC004 SI5002 IGT205 O1D100 PQ3834 IFS204 TA2105 IFM216 EVF566 II5930 II5697 EVC002 IG5596 SI5010 II5687 KF5015 VTV122 SA5000 E21248 PN3094
SI6700 E30448 OY039S EY3099 E11855 G1501S E11252 PM1608 AL1930 EVC146 EVT006 LI5131 PT5404 PN7299 PN7209 AC1254 AC1258 SI6800 EC2082 AL1102 UGT524 EVC086 EVC003 OGH500 II5689 AC5222 AC5218 AC5233 SU7000 PN3093 PN2160 IM5115 SH0500 LR2050 MVQ101 IFC248 IFC234 IFC220 IN5225 IFT203 O5E700 IG6086 E12339 IGC222 EVC714 IGW201 IF5888 EVC597 IM5126 IGT220 IG5505 IG5401 EVS023 EVC812 VTV121 IIS204 IM0011 SM9000 IGT213 IFT205 PN2093 PN2094 E20005 OGE101 OGS100 PM1506 E33403 SD1540 SD6101 SD6501 SD8501 SD2501 SD8000 SD6020 SD6800 SD5500 SD6500 SD6601 SD8601 SD8500 SD1440 SD1540 SD5600 SD6050 SD5100 SD2500 SD6600 SD5000 SD8600 SD9500 SD5800
We mainly supply Yokogawa,Emerson, Rosemount,Fisher,Honeywell,Siemens, ABB,FLUKE, Schneider Electric, Pepperl+Fuchs,MTL,Rockwell(Allen Bradley), Hirschmann, Eaton ,Moeller,FUJI,Omron, Yaskawa,Norgren,CHINT,Hach,Weidmuller,Phoenix, SMC,Testo, ASCO,Parker,Mitsubishi, Festo,GE, CISCO,Auma,IFM,GM,Turck,MOXA, Foxboro, Krohne, Swagelok, LS, Advantech, Dwyer,Endress Hauser, Bently Nevada,Moog etc.
We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.
Contact: